Master Controller 2.0v24
Reverse Cycle Defrost System
Installation & Operations Manual
An Electronic Microprocessor-Based
Electric/Mechanical Expansion Valve Refrigeration Control System
With TCP/IP Internet Monitoring Feature
May 2015
PN 888-88889
©2015 Master-Bilt Products, an unincorporated division of Standex International Corporation. All rights reserved.
Printed in U.S.A.
Zobrazit stránku 0
1 2 3 4 5 6 ... 30 31

Shrnutí obsahu

Strany 1 - Reverse Cycle Defrost System

Master Controller 2.0v24 Reverse Cycle Defrost System Installation & Operations Manual An Electronic Microprocesso

Strany 2 - IMPORTANT NOTICES

10Sequences of Operation START UP When power is applied to the board, the controller closes the valve. The controller will display ‘STUP’ on its fo

Strany 3

11If the suction pressure is above the maximum operating pressure set point (MOP), the valve will modulate to control the pressure at

Strany 4 - INTRODUCTION

12Demand Defrost When “DINM” = “DEMD” and ‘DFPD’ is set to ‘0’, the controller will initiate a demand defrost. The controller will not go to ‘DEFR

Strany 5 - APPLICATIONS

13o Defrost Mode  If this alarm and defrost term temp sensor alarm, reverse cycel defrost will last only three minutes with valve open;  If

Strany 6 - MASTER CONTROLLER

14 BOND CONTROLLERS FROM FRONT PANEL • Connect to Ethernet switch or router only the controllers that you want to bond. • On any controller, using

Strany 7

15Definition of On-Board Symbols STATUS, DEFAULT AND READING DISPLAY When the on-board green light is on, the compressor relay is energized. When

Strany 8 - Factory-Mounted Parts

16TYPICAL SET POINTS FOR AMC CONTROLLER 2.0 SETPOINT [email protected] Air/Electric Defrost Reverse Cycle Defrost “STPT” DESCRIPTIONS

Strany 9 - Features

17ALARM DISPLAY Any alarm will cause alarm relay to switch. All alarms have a distinct display shown on the four-digit display on the controller. Th

Strany 10 - Sequences of Operation

18 MANUAL VALVE Press the right or left button until ‘MNMD’ (Manual Mode) is displayed. Press the ‘ENTER’ button. If ‘PSWD’ (Password) is displaye

Strany 11 - IMPORTANT NOTE:

19SUCTION LINETEMP SENSORFAN DELAYPRESSURETRANSDUCERDEFROST TERMINATIONTEMP SENSOR6" TO 10"EVAP OUTTemperature Sensors The application r

Strany 12

2 IMPORTANT NOTICES • Read this manual before installing your Master Controller 2.0 system. Keep the manual and refer to it before doi

Strany 13

20Chart A. Temperature/Resistance Characteristics (-50 to 80 oF) Temp. oF Temp. oC ohms*1k Temp. oF Temp. oC ohms*1k -50 -45.6

Strany 14

21Charging the Master Controller 2.0 Refrigeration System Note: If you are a first time installer of a Master Controller 2.0 system, please call Ma

Strany 15

22The recommended charging procedures are: (1) Charge the system by weighing exact amount of refrigerant specified by Master-Bilt for the unit. Or,

Strany 16 - 10 10

23REVERSE CYCLE DEFROST General Information Master-Bilt’s patented (U.S. patent no. 7,073,344) reverse cycle defrost is a standard feature on Mast

Strany 17

24Eliminated Parts The Master-Bilt Reverse cycle’s unique technology, coupled with the bi-flow electric expansion valve, eliminates the need for: •

Strany 18

25TYPICAL WIRING DIAGRAM (AIR DEFROST) N.O.

Strany 19 - Temperature Sensors

26TYPICAL WIRING DIAGRAM (REVERSE CYCLE DEFROST) N.O.

Strany 20 - Pressure Transducer

27TYPICAL WIRING DIAGRAM (ELECTRIC DEFROST) Note: For feature configuration, please refer to the wiring diagram in the actaul system for instal

Strany 21 - Bilt for on-phone training

28TROUBLESHOOTING GUIDE. Trouble, Alarm Codes Causes Corrective Actions Pressure transducer alarm PRSA • Bad transducer • Out of range • Loose w

Strany 22 - Technical Notes

29Troubleshooting the Electric Expansion Valve If the valve stops moving, depending upon how far open it is, one or more alarms may be displayed. T

Strany 23 - REVERSE CYCLE DEFROST

3TABLE OF CONTENTS INTRODUCTION ... 4

Strany 24

30 908 Highway 15 North New Albany, MS 38652 Service Dept. phone: 800-684-8988 Fax: 866-882-7629 Email: service@mas

Strany 26

4INTRODUCTION Thank you for purchasing a Master-Bilt Master Controller 2.0 for Electric or Reverse Cycle Defrost system. This manual contains impor

Strany 27

5WARNING LABELS AND SAFETY INSTRUCTIONS This is the safety-alert symbol. When you see this symbol, be alert to the potential for personal injury o

Strany 28 - TROUBLESHOOTING GUIDE

6MASTER CONTROLLER Description The Master Controller 2.0 is a custom-designed microprocessor-based electronic controller for Master-Bi

Strany 29 - MASTER-BILT PART NUMBERS

7 • SEI or SER Terminals. Sporlan SEI and SER type electric expansion valves are currently used for all applications. There are 1596 nomi

Strany 30

8PressureT1 T2T3TransducerValveElectricLiquid LineEvaporatorDefrost Temp. SensorEvap Coil In/DistributorRoom Temp SensorTemp SensorEvap out / Fan Del

Strany 31

9Features • One of the most energy-saving features of the Master Controller 2.0 Reverse Cycle Defrost system is free floating head pressure. A hea

Komentáře k této Příručce

Žádné komentáře